Leak Detection dye

LUYOR-6220 Fluorescent Water-based Penetrant

LUYOR-6220 Fluorescent Water-based Penetrant

Detailed

 

LUYOR-6220 Fluorescent Water-based Penetrant

Technical Data Sheet
Description: LUYOR-6220 is a level 2, Method A water washable fluorescent penetrant for inspecting castings, extrusions and similar parts. LUYOR-6220 is a versatile, general purpose penetrant for use on a variety of materials, including aluminum and magnesium. LUYOR-6220 has been used by aerospace, airframe, turbine engine, and missile manufacturers for over a decade.

Chemical Properties
Color: Green
Viscosity: 6.46 cSt @ 1000F
Fluorescence: Yellow/Green
Water Tolerance: 15%
Flash Point: 2200F (104.40C)

Packaging
One Gallon Cans
55 Gallon Drums
Five Gallon Cans

Storage /Shelf Life
Keep away from moisture and sunlight.
Temperature limit: 400F to 1250F (0-500C)
Keep the container closed when not in use.
Shelf life from invoice date: Bulk Container – 36 months

Special Features
1. Low to near zero background for assured indication visibility.
2. Sharp, precise flaw indication for rapid interpretation.
3. Excellent electrostatic spray capability.
4. Long material tank life due to formula stability and non-volatility.
5. Low material consumption (low drag out) due to low viscosity.
6. Clean, odorless product, vapor free atmosphere.
UV LED lamps

Instructions
Note: These instructions describe the basic process, but they may need to be amended by the user to comply with applicable specification and/or inspection criteria provided by the contracting agency.

1. Application: Apply LUYOR-6220 only to clean, dry surfaces by spraying, flowing, brushing or dipping.
2. Dwell Time: A 10 minute dwell time is suggested, although in many cases five minutes will suffice. When particularly tight cracks are suspected, or the part is especially critical,the dwell time may be extended to 30 minutes, or longer. Allow the penetrant to drain
from the part surface back into the penetrant tank to conserve material.
3. Removal:
A) Use ambient temperature water to rinse LUYOR-6220 from the part surface. To avoid washing entrapped penetrant from surface flaws, do not use high water pressure or temperatures and avoid prolonged washing times.
B) Solvent Wipe Method – Remove as much excess penetrant as possible using clean dry rag or toweling. Remove remaining penetrant film by wiping with a rag or toweling that has been slightly moistened with solvent. Use a minimum of solvent; avoid flushing penetrant from flaws. Do not spray solvent directly on the part surface when removing excess penetrant. Rough surfaces require more generous application of solvent.
4. Drying: A re-circulating oven set no higher than 1600F (710C) is suggested. Leave the part in the oven just long enough to evaporate surface moisture. Drying is improved by using pressurized air to disperse and remove as much excess water as possible before placing the part in to the oven.
5. Developing: Apply the developer by cloud dusting, spray or dip using the appropriate developer. Flaw marks are visible under black light almost immediately, but allow sufficient developing time to enhance the flaw visibility.
6. Inspection: Inspect parts under appropriate UV-A light intensity and minimal visible light.

Remarks:Fluid Leak Detection
UV fluorescent additive is mixed with a fluid system, e.g. water, oils, fuels, coolants and refrigerants. The equipment is then operated as normal to allow the fluorescent additive to circulate throughout. Inspection under UV blacklight of all external surfaces, pipework, joints and coils will reveal leaks as a bright fluorescent yellow/green glow. This process can be used for routine quality control or trouble shooting procedures and offers improved probability of fluid leak detection.
Hits:  【Printing】  【Close】
  Next:LUYOR-6100 leak detection fluorescent dye
product|about us|news|distributors|guestbook|contact us|download

Copyright © 2008-2014 LUYOR Corporation. All Rights Reserved.

North America:Toll Free: 800.567.8335, fax: +1-604-942-9565, e-mail:info@luyor.net
China: toll free:4006-254-365 fax:021-51861392,e-mail:china@luyor.net

Copyright © 2008-2014 LUYOR NDT Corporation. All Rights Reserved.

ndt lamps |  Blacklight | Leak Detection Lamps |UV Flashlight